- 18 -
11. LOAD CELL SIGNAL CONDITIONER BOARD JUMPER SETTINGS
Five ranges are jumper selectable. These also have to be selected in Instrument Setup software.
1. Use 2.5 mm (0.1") jumpers
.
2. Store spare jumpers on an unused jumper post.
Load Cell & Microvolt Ranges
FS Input Jumpers
±20.000 mV
±50.000 mV
±100.00 mV
±250.00 mV
±500.00 mV
e
a
b
c
d